PHOTOVOLTAIC SYSTEM CONTROLLERS
O
PERATOR
S
M
ANUAL
P
RORO
S
TARTAR
MODEL RATINGS
P
RO
S
TAR
-12 P
RO
S
TAR
-20 P
RO
S
TAR
-30
Rated PV current 12A 20A 30A
Rated Load current 8A 16A 30A
System voltage: 12 and 24 volts, auto selected
ProStar models • Standard
included in this • With LCD meter
manual:
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1

PHOTOVOLTAIC SYSTEM CONTROLLERSOPERATOR’SMANUALPROROSTARTARMODEL RATINGSPROSTAR-12 PROSTAR-20 PROSTAR-30Rated PV current 12A 20A 30A Rated Load curren

Strany 2 - PRECAUTIONS

105.0 OPERATION5.1 CONTROLLEROPERATIONThe ProStar is a fully automatic PV system controller thatincludes many electronic functions to protect both th

Strany 3 - 2.0 QUICK START INSTRUCTIONS

11Automatic Safety • Load Short-Circuit: Instant loadDisconnects disconnect. The LED’s flash in sequence. Battery must be disconnected to clear and re

Strany 4 - 3.1 LED I

126. Inspect for dirt, insects, nests, and corrosion.7. Check that the controller functions and LED indicators arecorrect for the system conditions at

Strany 5 - All LED’s

13the battery. This will cause undercharging of the battery. See section 4.2-4.g. Check the condition of the battery. Determine if the batteryvoltage

Strany 6 - NDICATIONS

14d. If there is a problem with high voltage, the controller shouldgo into the High Voltage Disconnect mode (see section 5.2). 3. LOADNOTOPERATINGPRO

Strany 7 - INSTALLATION STEPS:

6.0 TECHNICAL SPECIFICATIONS15MECHANICAL• Dimensions: (inches) ... 6.01 (W) x 4.14 (H) x 2.17 (D)(mm) ... 153 (W) x 105 (H) x 55 (

Strany 8

P.O. BOX958OLNEY, MARYLAND20830 USAR1- APRIL 1996

Strany 9

2CONTENTS1.0 GENERALINFORMATION... 22.0 QUICKSTARTINSTRUCTIONS...

Strany 10 - 5.0 OPERATION

3• Even though the system is only 12 or 24 volts, both the PVarray and battery can contain lethal amounts of electricalpower.• Do not splash water on

Strany 11 - AINTENANCE

43. Connect the BATTERYfirst. Observe that all LED’s flash insequence one time.4. Connect battery SENSEleads (if utilized). This is recom-mended if th

Strany 12 - ROUBLESHOOTING

5BATTERY CHARGEGreen ON: Battery near full charge BATTERY CHARGEYellow ON: Battery at middle capacity (about 35% to 80% SOC)NOTE: does not indicate a

Strany 13

64.0 INSTALLATION INSTRUCTIONS4.1 POLARITYPROTECTION(ANDLED INDICATIONS)CAUTION: Although the ProStar is fully protected fromreversed polarity, the s

Strany 14 - BATTERY CHARGE

74.2 INSTALLATIONPROCEDUREGENERAL INSTALLATION NOTES:• The ProStar prevents reverse current leakage at night, so a blocking diode is not required in t

Strany 15 - 6.0 TECHNICAL SPECIFICATIONS

8Multiple ProStar units can be paralleled at the system battery,but be careful that no PV sub-array exceeds a controller’sindividual current rating.3.

Strany 16 - 20830 USA

9CHARGINGindicator comes on after 2 minutes to confirmthat the PV array has been properly connected.6.LOAD (+ and -)Turn the load off. Connect the loa

Komentáře k této Příručce

Žádné komentáře